EasyManuals Logo
Home>Delta>Inverter>RPI M6A

Delta RPI M6A Operation And Installation Manual

Delta RPI M6A
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
Figure 5-27 Cosphi (P) parameters
Figure 5-28 Q(V) page
5.3.7.6. Constant Q
Like Constant cosphi function, users can assign a percentage of reactive
power in Constant Q page.
5.3.7.7. Q(V)
Q(V) is a control mode that inverter will provide reactive power accroding
to grid voltage. For country Italy MV and Italy LV, users can set lock-in
power and lock-out power to assign Q(V) function operation interval.
Constant cosphi
Cosphi (P)
Constant Q
Q(V)
Mode
Fix Q
OFF
Ind 90%
EXIT
ENT
Constant cosphi
Cosphi (P)
Constant Q
Q(V)
Mode
V1s
V2s
Qs limit
OFF
248.4V
253.0V
Ind 44%
V1i
V2i
Qi limit
T delay
211.6V
207.0V
Cap 44%
10.00s
P lock-in
P lock-out
20%
5%
EXIT
EXIT
EXIT
ENT
39
Turn on/off PV inverter

Other manuals for Delta RPI M6A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta RPI M6A and is the answer not in the manual?

Delta RPI M6A Specifications

General IconGeneral
BrandDelta
ModelRPI M6A
CategoryInverter
LanguageEnglish

Related product manuals