20
Beam Delivery Cable (Fibre)
The beam delivery cable is not Class 1 under a worst case single fault,
no cable break or fibre break detection is offered on this product. The
integrator must either include the beam delivery cable inside the Class
1 enclosure with the Pulsed Laser Aperture or undertake suitable
measures to ensure that under reasonable use, the cable is suitably
positioned to prevent it from becoming damaged or mishandled.
The beam delivery cable has not been designed for robotic
applications. The Laser must not be designed into systems where the
Beam Delivery Cable will be subject to high levels of acceleration,
torsion and twist, or combination thereof. If this is a requirement for the
integration, please contact Domino to discuss the application in more
detail.
The minimum bedding radius (r) for the fibre is 75mm.