Interlock Switches
Interlock switches must be fitted to all access guards preventing access
to the laser output lens and marking area that can be opened without
the use of access tools.
Interlock switches must be wired into the laser control circuit so that the
laser beam is disabled when the guard is removed.
Emergency Off
Integrate the laser into the emergency off circuit of the machine into
which the laser is integrated. Install an emergency off push button near
the laser marking systems which turns off the laser. Connect the
emergency off push button via the interlock circuit to the controller.
Guarding Labels
Domino recommend that the following information is prominently
displayed on the guard:
WARNING: Class 1 laser product containing an embedded
class 4 laser.
Operation of the product with safety guards
removed may result in hazardous exposure to
laser radiation.
These labels are supplied with the laser system. Additional labels are
available from Domino Printing Sciences plc as part of the Guarding
Labels Kit, Part Number L007628.

Table of Contents

Other manuals for Domino F Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Domino F Series and is the answer not in the manual?

Domino F Series Specifications

General IconGeneral
BrandDomino
ModelF Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals