Chapter 4
4. After successfully initiating the arming sequence the:
l
Armed indicator turns on.
l
Ready indicator remains lit.
l Exit Delay timer begins counting down.
l Keypad beeps six times, continues beeping once per second
until beeping rapidly in the final ten seconds.
l The system may be configured to have a persistent exit delay that
only ends when the exit door is opened and closed, or when a
button is pressed outside the protected premises.
Exit Delay in
Progress
5. To cancel the arming sequence, enter your [access code] or present
your proximity tag to the keypad reader.
System Disarmed
No Alarm Memory
6. Once the exit delay timer expires, thereby arming the system, the:
l Ready indicator turns off.
l Armed indicator remains on.
l Keypad stops sounding.
System Armed
in Away Mode
NOTE: The installer configures the exit delay timer and whether or not an access code is required for arm-
ing the system.
4.2 Stay Arming the System with the Keypad
Stay mode partially activates your alarm system by:
l Arming all perimeter sensors.
l Bypassing all interior sensors.
To Arm the System in Stay mode:
LCD Display
1. Ensure all windows and doors are closed and that the Ready indicator
is on.
Date Time
JAN 02/18 2:06a
2. Press and hold the Stay key for 2 seconds and, if required, enter your
access code or present your proximity tag. Do not leave the premises.
System is
Ready to Arm
then
Enter Your
Access Code
3. If zones have been bypassed, ICN or LED keypads bypass LED will
light and the bypassed zones numbers will be shown. On an LCD
keypad a warning appears.
* Warning *
Bypass Active
4. After successfully initiating the arming sequence the:
l
Armed indicator turns on.
l
Ready indicator remains lit.
l Exit Delay timer begins counting down.
Exit Delay in
Progress
5. To cancel the arming sequence, enter your [access code] or present
your proximity tag.
System Disarmed
No Alarm Memory
6. Once the exit delay timer expires, thereby arming the system, the:
l
Ready indicator turns off.
l
Armed indicator remains on.
l Bypass or system indicator activates.
System Armed
in Stay Mode
NOTE: When using a proximity tag and a Stay/Away zone is programmed, the system arms in Away
mode if a delay zone is tripped. If there is no Stay/Away zone, the system always arms in Away mode.
4.2.1 Silent Exit Delay
If the system is armed using the Stay key or the No Entry Arming method [*][9]:
l The warning beep is silenced.
l The exit time is doubled for that exit period only (CP-01 versions only).
NOTE: For non CP-01 versions, Standard Exit Time is used.
- 11 -