Chapter 5
If the Carbon Monoxide Alarm Sounds
1. Operate Silence button.
2. Call emergency services or your fire department.
3. Immediately move outdoors or to an open door/window.
5.1.2.1 CO Alarm Bells Silenced
CO alarms can be silenced by entering a valid access code. The mes-
sage shown will be displayed on a LCD or touch screen keypad. The
message will not be cleared until CO zones have been restored on sys-
tem.
CO Alarm < >
Bells Silenced
5.1.3 Intrusion (Burglary) Alarm - Continuous Siren
!
If you are unsure of the source of the alarm approach with caution!
If the Intrusion alarm was accidental
1. Enter your Access Code to silence the alarm. If the code is entered within 30s (or the programmed
value of the alarm transmission delay) the transmission of the alarm to the monitoring station will be
cancelled.
2. Call your central station to avoid a dispatch.
5.1.4 Alarm Cancel Window
The control panel provides a period of time in which the user can cancel the alarm transmission. If the
programmed alarm transmission delay has expired, canceling an alarm sends a message to the mon-
itoring station. Upon a successful transmission of the cancellation message the keypad will beep 6 times.
NOTE: Must be enabled and configured by installer.
NOTE: For CP-01 systems, alarm transmission delay must not exceed 45 seconds.
5.1.5 Viewing Alarms in Memory
When an alarm occurs the keypad indicator illuminates. Viewing the Alarm memory provides more inform-
ation on the sensor(s) that were tripped. When using an ICON or LED keypad the Memory LED will be lit
and the zone numbers will be displayed.
To View Alarms in Memory LCD Display
l Press [*][3] or
use the scroll keys to navigate to Alarm Memory and press . The
Alarm information will display. For more information on the mes-
sages that could be displayed see: “Alarm Messages”.
Press (*) for <>
Alarm Memory
Alarm Messages
LCD Display What it means
Burglary <>
Verified
Multiple burglary sensors were tripped. Central station has been noti-
fied.
Burglary Not <>
Verified
A single burglary sensor was tripped. Central station has been noti-
fied.
Hold-up <>
Verified
Multiple hold-up sensors were tripped. Central station has been noti-
fied.
Hold-up Not <>
Verified
A single hold-up sensor was tripped.
Fire Alarm <>
Fire Zone 1
Fire alarm has been triggered. Central station has been notified. On
an ICN or LED keypad the will be lit.
CO Alarm <>
CO Zone 1 <>
CO alarm has been triggered. Central station has been notified. On
an ICN or LED keypad the will be lit.
- 19 -

Table of Contents

Other manuals for DSC PowerSeries Neo HS2016-4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PowerSeries Neo HS2016-4 and is the answer not in the manual?

DSC PowerSeries Neo HS2016-4 Specifications

General IconGeneral
BrandDSC
ModelPowerSeries Neo HS2016-4
CategorySecurity System
LanguageEnglish

Related product manuals