Chapter 4
4.3 Night Arming the System with the Keypad
Night mode partially activates the alarm system by:
l Bypassing all internal sensors configured as Night zones.
l Arming all perimeter sensors.
l Armingall other internal sensors.
Arming the system in Night mode is possible after the system has first been armed in Stay mode and [*][1]
is pressed at the keypad. The keypad can also be configured with a function key to arm the system in
Night mode. To access armed interior areas when the system is armed in Night Mode, you must disarm
the system.
NOTE: Ensure that your installer has provided you with a list identifying all programmed night zones.
Your installer can configure a function key to arm the panel in Night mode without the system already
being armed in Stay mode.
To Arm the System in Night mode:
LCD Display
1. If configured, press and hold the Night Arm key for 2 seconds. OR
2. Once the system is armed in Stay mode (Armed indicator is on) at
any keypad press [*][*].
OR
press[*][1].
Date Time
JAN 02/19 2:06a
then
Press (*) for <>
Interior Arm
3. If required, enter your access code. All interior zones will be armed,
except for devices programmed as Night Zones.
l
The Night Mode icon turns on.
Present Tag or
Enter Code
then
Interior Has
Been Armed
To gain access to interior areas that are armed during Night mode disarm the system by entering your
[access code].
4.4 No-Entry Arming
No-Entry Arming arms the system in Stay mode by:
l Removing the Entry Delay from all configured zones.
l Arming all perimeter sensors.
l Bypassing all interior sensors.
An entry through any zone will create an instant alarm.
To arm the system in No-Entry mode:
LCD Display
1. Check that the Ready indicator is on and your system is ready to
be armed.
Date Time
JAN 02/18 2:06a
2. Press [*][9] and, if required, enter your [access code].
Present Tag or
Enter Code
3. If zones have been bypassed, ICN or LED keypads bypass LED will
light and the bypassed zones #s will be shown. On an LCD keypad
a warning appears.
* Warning *
Bypass Active
then
4. After successfully initiating the arming sequence the:
l Armed light flashes as a reminder that the system is armed and
has no entry delay.
l Keypad sounds fast beeps.
l Keypad displays “Exit Delay in Progress”.
Armed With No
Entry Delay
then
Exit Delay in
Progress
5. To cancel the arming sequence, enter your [access code] or present
your proximity tag.
System Disarmed
No Alarm Memory
6. Once the exit delay timer expires, the system is armed.
System Armed
in Stay Mode
- 12 -