EasyManuals Logo
Home>Epiroc>Industrial Equipment>EC 40T

Epiroc EC 40T User Manual

Default Icon
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
Safety and operating instructions
© Construction Tools GmbH | 3390 5203 01 | 2019-08-06
Original Instructions
25
NOTICE Total damage to the hydraulic attachment
Polluted hydraulic lines and connections may enable
sand, fragments of material and dirt to penetrate the hy-
draulic attachment and damage it completely.
u Clean the hydraulic lines and connections before
connecting the hydraulic hoses. Lay all hydraulic
hoses so that they are torsion-free.
n
Install the pressure and tank hoses.
n
Connect the pressure and tank hoses.
n
If no quick couplings are used, open the shut-off
valves in the installation at the boom.
n
Switch on the carrier.
n
Let the hydraulic oil run through the carrier oil filter for
approx. three minutes to make sure that the hoses
are clean.
n
Switch off the carrier.
n
Depressurise the hydraulic system according to the
manufacturer's safety and operating instructions for
the carrier.
n
If no quick couplings are used, close all shut-off
valves in the installation at the boom.
n
Disconnect the pressure and tank hoses.
WARNING Components bursting
Components of the swivel joint may burst. Metal parts
may become projectiles and cause serious injuries and
damage property.
u Always check the swivel joint covers are fitted prop-
erly when attaching the hydraulic breaker to the car-
rier.
u Tighten loosen screw connections (see chapter Bolt
connections / Tightening torques).
u Immediately replace a defective swivel joint cover.
n
Remove the caps from the ports »P« and »T« and
save them for future use.
The pressure port »P« has been marked with red
paint as an extra reference.
n
Check that the ports and connections on the hy-
draulic breaker and/or on the hydraulic hoses are not
damaged.
n
Replace any damaged connections.
n
Connect the pressure hose to port »P«, making sure
it is torsion-free.
n
Connect the tank hose to port »T«, making sure it is
torsion-free.
WARNING Hydraulic hose flailing about
Pressurised hydraulic hoses will flail about if a bolted
connection comes loose or becomes loosened. A hy-
draulic hose flailing about may cause serious injuries.
u Tighten the fastening screws with the right tightening
torque.
Tightening torque (see chapter Bolt connections /
Tightening torques).