Safety and operating instructions
© Construction Tools GmbH | 3390 5203 01 | 2019-08-06
Original Instructions
27
n
Lift the adapter plate with a suitable lifting equipment
and put it down on timber support blocks.
n
Lock the elastic pad with the transport safety device.
n
Save the fastening screws and the pairs of lock
washers for future use.
5.7 DustProtector
n
Place the hydraulic breaker on timber support blocks.
WARNING Unexpected movement
Sudden movements of the carrier may cause serious in-
jury.
u Secure the carrier such that it cannot move unex-
pectedly.
u Observe the carrier manufacturer’s instructions.
WARNING Metal chips shooting off
When hammering out bolts, chips may shoot off and
cause serious eye injuries.
u Wear safety glasses when hammering out the bolts.
5.7.1 Removal
n
Remove the working tool (see chapter Working tool/
Removal) before removing the DustProtector.
n
Remove the plugs(B) from the breaker box.
n
Drive out the lock bolts(C) of the DustProtector using
a pin punch and a hammer.
n
Remove the guide ring(F), floating ring(E) and
counter ring(D) of the DustProtector system.
n
Remove the wiper(A).
To make the wiper(A) easier to remove: Push the seal-
ing lip of the wiper inwards with your thumb. This pushes
the wiper out of the wiper sleeve ring groove.
5.7.2 Installation
n
Before installing the DustProtector, install the working
tool (see chapter Working tool/Installation).
n
Manually push the wiper(A) over the working tool
and let it click into place in the wiper sleeve ring
groove.
n
Use a tool (hammer handle) to push on the wiper(A)
at several points.
n
Use your thumbs to push the wiper into place along
its circumference.
n
Apply chisel paste to the guide ring(F), floating
ring(E) and counter ring(D).
n
Install the floating ring(E) and counter ring(D) in the
guide ring(F).
n
Push the rings over the working tool and install them
in the lower part of the breaker box.
n
Turn the guide ring(F) so that the apertures in the
breaker box and the guide ring are lined up.
n
Drive the lock bolts(C) into place using a pin punch
and a hammer.
n
Seal the apertures in the breaker box with the
plugs(B).