Safety and operating instructions
44 © Construction Tools GmbH | 3390 5203 01 | 2019-08-06
Original Instructions
7.4.5 Manual lubrication
Manual lubrication is required if the automatic lubrication
system fails to work.
n
Place the hydraulic breaker at a right angle on the
working tool and exert pressure.
n
Only use chisel paste for lubrication.
n
Put the manual grease gun on the grease nipple of
the emergency lubrication system and inject chisel
paste.
• Lubrication interval: approx. every 2 hours
• Hydraulic breaker without DustProtector: 5 to 15
strokes from the manual grease gun
• Hydraulic breaker with DustProtector: 5 to 10
strokes from the manual grease gun
7.4.6 Chisel paste filling device
Construction Tools GmbH offers a device for refilling
empty cartridges. This can be mounted on a 15-kg or 45-
kg hobbock to fill empty cartridges as required.
Bio chisel paste
550-g Bio chisel paste cartridges packed per 12 car-
tridges:
part number 3363 1223 56 for ContiLube
®
II
15-kg Bio chisel paste container,
part number 3363 1223 57
45-kg Bio chisel paste container,
part number 3363 1223 58
Chisel paste
500-g chisel paste cartridges packed per 12 cartridges:
part number 3363 0912 00 for ContiLube
®
II
15-kg chisel paste container,
part number 3362 2639 00
45-kg chisel paste container,
part number 3362 2632 75
Manual grease gun for ContiLube
®
II cartridges:
part number 3363 0345 67
Filling device for use with 15-kg containers:
part number 3363 0946 69
Filling device for use with 45-kg containers:
part number 3363 0664 11
For further information, please contact the Epiroc Cus-