Safety and operating instructions
© Construction Tools GmbH | 3390 5203 01 | 2019-08-06
Original Instructions
65
12 Technical specifications
HB3100, HB3100DP HB3600, HB3600DP
Carrier weight class
1)
32 - 52t
(70500 - 115000lbs)
35 - 63t
(77000 - 139000lbs)
Service weight
2)
3100kg (6800lbs) 3600kg (7900lbs)
Delivery weight (Standard version)
4)
2522kg (5560lbs) 2965kg (6540lbs)
Delivery weight (DustProtector version)
4)
2574kg (5670lbs) 3040kg (6700lbs)
Oil flow rate 210 - 270l/min
(55.5 - 71.3 gal/min)
240 - 300l/min
(63.4 - 79.3 gal/min)
Operating pressure 160 - 180bar
(2320 - 2610psi)
Impact rate AutoControl
(280 - 560 blows/min)
Working tool diameter 165mm (6.50in.) 170mm (6.69in.)
Working length of working tool (Standard version) 675mm (27in.) 700mm (28in.)
Working length of working tool (DustProtector version) 630mm (25in.) 650mm (26in.)
Max. hydraulic input power 81kW (108.6hp) 90kW (120.7hp)
Back pressure acceptance
8)
30bar (435psi)
Gas pressure HP- accumulator (20°C (68°F)) 60bar (870psi)
Air pressure (min. gauge pressure in percussion chamber)
5)
1.5bar (22psi)
Air flow (up to depth of 10meters (33ft))
6)
5 m
3
/min (177 cfm)
Max static pressure (pressure relief valve on carrier) 200bar (2900psi)
Piston accumulator gas pressure (min, at operating tempera-
ture 60-70°C (140-158°F))
7)
14.2bar (206psi) 11.5bar (167psi)
Piston accumulator gas pressure (max (optimum), at operating
temperature 60-70°C (140-158°F))
7)
16.7bar (242psi) 14.0bar (203psi)
Hose inside diameter »P« 32mm (1.3in.)
Hose inside diameter »T« 32mm (1.3in.)
Start up mode IPS
1)
Weights apply to standard carriers only. Any variances must be agreed with Epiroc and/or the carrier manufacturer
prior to attachment
2)
Hydraulic breaker incl. breaker box, working tool and adapter plate of medium size. Please note that the service
weight can be considerably higher, depending on the adapter plate.
4)
Hydraulic breaker, breaker box and ContiLube
®
II without working tool and adapter plate
5)
Air pressure at pressure regulator has to be adjusted to 1.5bar + 0.1bar per meter depth (22psi + 0.5psi/ft depth)
6)
Air flow for depth of more than 10meters (33ft): Flow = 0.1 x depth[m] x flow up to 10meters [m
3
/min] (0.0305 x
depth[ft] x flow up to 33ft[cfm])
7)
Hydraulic breaker in horizontal position, no pressure applied to working tool
8)
Back pressure acceptance when breaker still runs regular but at significant reduced performance (oil flow)