Safety and operating instructions
66 © Construction Tools GmbH | 3390 5203 01 | 2019-08-06
Original Instructions
HB4100, HB4100DP HB4700, HB4700DP
Carrier weight class
1)
40 - 70t
(88000 - 154000lbs)
45 - 80t
(99000 - 176000lbs)
Service weight
2)
4100kg (9000lbs) 4700kg (10400lbs)
Delivery weight (Standard version)
4)
3420kg (7540lbs) 3845kg (8480lbs)
Delivery weight (DustProtector version)
4)
3516kg (7750lbs) 3930kg (8660lbs)
Oil flow rate 250 - 320l/min
(66.0 - 84.5 gal/min)
260 - 360l/min
(68.7 - 95.1 gal/min)
Operating pressure 160 - 180bar
(2320 - 2610psi)
Impact rate AutoControl
(280 - 550 blows/min)
AutoControl
(280 - 540 blows/min)
Working tool diameter 180mm (7.09in.) 190mm (7.48in.)
Working length of working tool (Standard version) 750mm (30in.) 790mm (31in.)
Working length of working tool (DustProtector version) 705mm (28in.) 730mm (29in.)
Max. hydraulic input power 96kW (128.7hp) 108kW (144.8hp)
Back pressure acceptance
8)
30bar (435psi)
Gas pressure HP- accumulator (20°C(68°F)) 60bar (870psi)
Air pressure (min. gauge pressure in percussion chamber)
5)
1.5bar (22psi)
Air flow (up to depth of 10meters (33ft))
6)
6 m
3
/min (212 cfm) 7.5 m
3
/min (265 cfm)
Max static pressure (pressure relief valve on carrier) 200bar (2900psi)
Piston accumulator gas pressure (min, at operating tempera-
ture 60–70°C(140–158°F))
7)
11.7bar (170psi) 10.5bar (152psi)
Piston accumulator gas pressure (max (optimum), at operating
temperature 60–70°C(140–158°F))
7)
14.2bar (206psi) 13.0bar (189psi)
Hose inside diameter »P« 32mm (1.3in.)
Hose inside diameter »T« 32mm (1.3in.)
Start up mode IPS
1)
Weights apply to standard carriers only. Any variances must be agreed with Epiroc and/or the carrier manufacturer
prior to attachment
2)
Hydraulic breaker incl. breaker box, working tool and adapter plate of medium size. Please note that the service
weight can be considerably higher, depending on the adapter plate.
4)
Hydraulic breaker, breaker box and ContiLube
®
II without working tool and adapter plate
5)
Air pressure at pressure regulator has to be adjusted to 1.5bar + 0.1bar per meter depth (22psi + 0.5psi/ft depth)
6)
Air flow for depth of more than 10meters (33ft): Flow = 0.1 x depth[m] x flow up to 10meters [m
3
/min] (0.0305 x
depth[ft] x flow up to 33ft[cfm])
7)
Hydraulic breaker in horizontal position, no pressure applied to working tool
8)
Back pressure acceptance when breaker still runs regular but at significant reduced performance (oil flow)