7.4.2 Automatic lubrication
The hydraulic breaker is lubricated automatically by the
ContiLube
®
II.
The ContiLube
®
II has been installed near the service
opening in the upper section of the breaker box.
Instructions on how to operate and maintain the Con-
tiLube
®
II is described in a seperate documentation.
n
If you have questions how to use the ContiLube
®
II,
contact the Epiroc Customer Center / dealer in your
area.
7.4.3 Replacing the lubricant cartridge
n
Unscrew and remove the empty lubricant cartridge
and the old seal by turning counter clockwise.
n
Remove the cover from the new cartridge. Make sure
not to damage the sealing cone(A).
n
Place the seal(B) on the cartridge.
n
Use your thumb to push the cartridge piston down
until lubricant escapes from the screw thread.
n
Screw the cartridge until the stop into the guide hole
of the grease pump.
The ContiLube
®
II is ready for use.
7.4.4 ContiLube®II operation
Please remember the following:
The ContiLube
®
II (C) is self-venting, i.e. the system
does not require you to vent it.
The lubricant level in the transparent cartridge(E) of
recyclable PE plastic can always be checked from
the cab by looking at the position of the red piston.
The piston side of the cartridge(E) must never be
sealed, otherwise no grease supply will be possible.
You can change the supply volume by adjusting the
metering screw(A), depending on the actual use.
Tighten the screw clockwise = less grease
Loosen the screw counter-clockwise = more grease
C
B
A
D
E
The pump unit(C) must always be sealed to prevent the
ingestion of water and dust.
n
Use a dust cover or leave the empty cartridge in the
pump until a new cartridge is available.
n
Check the tightness of the connections of all hoses
for the ContiLube
®
II operation once a week.
Emergency lubrication is possible via the grease nip-
ple(B) on the side of the ContiLube
®
II.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epiroc EC 40T and is the answer not in the manual?

Epiroc EC 40T Specifications

General IconGeneral
BrandEpiroc
ModelEC 40T
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals