97
EN
cod. 3542B380 - Rev 00 - 05/2022
6. Conrmwiththe button. The value in the box will stop blinking.
NOTE Depending on the zone operating mode, the behavior will be as follows:
a. Zoneconguredinmanualmode:thesetpointischangedpermanently,andsavedasanewmanualsetpoint.
b. Zoneconguredinautomaticmode:thenewvalueenteredwillbeuseduntiltheendofthecurrenttimeband,
after which it will return to the value set in the time schedule.
NOTE If the current time band is changed, the set point will be reset after the previous programming
expires.
NOTE Following a power outage, when restarted the set point will return to the one programmed for
the current time band.
c. Zone off: the zone will switch to manual mode and the new value entered will be used as the set point.
5.6 DHW TEMPERATURE CHANGE
1. Regardless of the selected zone, go to the "DHW
SET POINT" area.
2. Press the
button. A screen will appear, where the
DHW set point value can be changed.
CRP
TUE
23/07/19 12:19
27.3
MENU MODE
16.0 °C
°C
g. 54
3. Modify the value using the buttons and .
4. Conrmwiththe
button.
ECO SETPOINT
44.5 °C
g. 55
NOTE The desired temperature can be varied in steps of 0.5°C. The minimum settable value is 30°C, the
maximum is 60°C.
5.7 COMFORT SETTING
5.7.1 SILENT MODE
The SILENT mode (if active) reduces the noise of the outdoor unit.
1. Follow the path:
“MENU >> SETTINGS >> SILENT FUNCTION”
2. Modify the value using the
and buttons: the permissible values are:
0: The silent function is deactivated
1: The silent function is activated
2: The silent function is activated in extra silent mode.
NOTE The extra silent mode is recommended in those times of the day (such as at night) when you want to
minimize the noise of the outdoor unit.