EasyManuals Logo

Fronius TransSteel 5000 Rob User Manual

Fronius TransSteel 5000 Rob
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #58 background imageLoading...
Page #58 background image
58
The amperage value is shown in the left-hand digital display.
All welding parameter set values that have been set using the adjusting dial remain
stored until the next time they are changed. This applies even if the power source is
switched on and off again in the meantime.
Start welding
To display the actual welding current during welding:
- Press the "Parameter selection" button to select the welding current parameter
- The actual welding current is shown in the digital display during welding.
Corrections dur-
ing welding
To obtain the best possible welding results, the arc-force dynamic parameter will some-
times need to be adjusted.
Press the "Parameter selection" button to select the arc-force dynamic parameter
Use the adjusting dial to set the desired arc-force dynamic value
The welding parameter value is shown in the digital display located above it.
HotStart function To obtain optimum welding results, it will sometimes be necessary to adjust the HotStart
function.
Advantages
- Improved ignition, even when using electrodes with poor ignition properties
- Better fusion of the base material during the start-up phase, meaning fewer cold-shut
defects
- Largely prevents slag inclusions
For details on setting the available welding parameters, please refer to "Setup parame-
ters", "Setup menu - level 2".
Legend
Hti: Hot-current time,
0 - 2 s, factory setting: 0.5 s
HCU: HotStart-current,
100 - 200 %, factory setting 150 %
I
H
: Main current = set welding current
Function
During the specified hot-current time (Hti),
the welding current is increased to a certain
value. This value (HCU) is higher than the
selected welding current (I
H
).
Anti-stick func-
tion
As the arc becomes shorter, the welding voltage may drop so far that the rod electrode will
tend to "stick". This may also cause "burn-out" of the rod electrode.
5
1
2
200
300
I (A)
Hti
HCU > I
H
t (s)
I
H
HCU
0,5 1 1,5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransSteel 5000 Rob and is the answer not in the manual?

Fronius TransSteel 5000 Rob Specifications

General IconGeneral
BrandFronius
ModelTransSteel 5000 Rob
CategoryPortable Generator
LanguageEnglish

Related product manuals