Poor weld properties
Cause: Incorrect welding parameters
Remedy: Check the settings
Cause: Poor ground earth connection
Remedy: Ensure good contact to workpiece
Cause: Inadequate or no protective gas shield
Remedy: Check the pressure regulator, gas hose, gas solenoid valve, torch gas con-
nection, etc.
Cause: Welding torch is leaking
Remedy: Change the welding torch
Cause: Wrong contact tip, or contact tip is worn out
Remedy: Replace the contact tip
Cause: Wrong wire alloy or wrong wire diameter
Remedy: Check the wire electrode that has been inserted
Cause: Wrong wire alloy or wrong wire diameter
Remedy: Check weldability of the base material
Cause: The shielding gas is not suitable for this wire alloy
Remedy: Use the correct shielding gas
The welding torch becomes very hot
Cause: The design dimensions of the welding torch are not sufficient for this task
Remedy: Observe the duty cycle and loading limits
Cause: Inadequate coolant flow
Remedy: Check coolant level, flow rate, contamination, etc., Coolant pump blocked:
Tighten the coolant pump shaft
Displayed service
codes
If an error message that is not described here appears on the displays, proceed as follows
to resolve the problem:
Turn the power source mains switch to the "O" position
Wait 10 seconds
Move the mains switch to the I position
If the error occurs again despite several attempts to eliminate it, or if the troubleshooting
measures listed here are unsuccessful.
Make a note of the error message displayed
Note down the configuration of the power source
Contact our After-Sales Service team with a detailed description of the error
1
2
3
1
2
3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransSteel 5000 Rob and is the answer not in the manual?

Fronius TransSteel 5000 Rob Specifications

General IconGeneral
BrandFronius
ModelTransSteel 5000 Rob
CategoryPortable Generator
LanguageEnglish

Related product manuals