SPb Spot break - stitch pause time
Unit: s
Setting range: OFF, 0.1 - 10 (in 0.1 s increments)
Factory setting: OFF
FAC Factory - Reset power source to factory setting
Press and hold down the "Dynamic" (manual control panel) or "Parameter selec-
tion" (Synergic A control panel) button for 2 seconds to restore the factory settings.
When "PrG" is shown on the digital display, the power source has been reset.
IMPORTANT! When the power source is reset, all the personal settings in the Set-
up menu are lost. When the power source is reset, operating points that were
saved using the "Save" buttons are not deleted, but are retained in the memory.
The functions in the second level of the Setup menu (2nd) are also not deleted. Ex-
ception: Ignition time-out function parameter (ito).
2nd Second level of the Setup menu (see "Setup menu - level 2")
Setup parameters
for MMA welding
IMPORTANT! If you reset the power source using the FAC factory setup parameter, the
hot-current time (Hti) and HotStart current (HCU) setup parameters are also reset.
HCU HotStart current
Unit: %
Setting range: 100 - 200
Factory setting: 150
Hti Hot-current time
Unit: s
Setting range: 0 - 2.0
Factory setting: 0.5
Ast Anti-Stick
Unit: -
Setting range: On, Off
Factory setting: Off
FAC Factory - Reset power source to factory setting
Press and hold down the "Dynamic" (manual control panel) or "Parameter selec-
tion" (Synergic A control panel) button for 2 seconds to restore the factory settings.
When "PrG" is shown on the digital display, the power source has been reset.
IMPORTANT! When the power source is reset, all personal settings are lost.
When the power source is reset, operating points that were saved using the "Save"
buttons are not deleted, but are retained in the memory. The functions in the sec-
ond level of the Setup menu (2nd) are also not deleted. Exception: Ignition time-
out function parameter (ito).
2nd Second level of the Setup menu (see "Setup menu - level 2")

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransSteel 5000 Rob and is the answer not in the manual?

Fronius TransSteel 5000 Rob Specifications

General IconGeneral
BrandFronius
ModelTransSteel 5000 Rob
CategoryPortable Generator
LanguageEnglish

Related product manuals