66
Setup parameters
for MIG/MAG
standard manual
welding
"Min." and "max." are used for setting ranges that differ according to power source, wire-
feed unit, welding program, etc.
GPr Gas pre-flow time
Unit: s
Setting range: 0 - 9.9
Factory setting: 0.5
GPo Gas post-flow time
Unit: s
Setting range: 0 - 9.9
Factory setting: 0.5
Fdi Feeder inching (speed)
Unit: m/min (ipm.)
Setting range: 1 - max. (39.37 - max.)
Factory setting: 10 (393.7)
SL Slope (special 4-step mode only)
Unit: s
Setting range: 0 - 9.9
Factory setting: 0.1
I-S I (current) - Starting - Starting current (special 4-step mode only)
Unit: % (of welding current)
Setting range: 0 - 200
Factory setting: 100
I-E I (current) - End: Final current (special 4-step mode only)
Unit: % (of welding current)
Setting range: 0 - 200
Factory setting: 50
t-S t (time) - Starting - Starting current duration (special 4-step mode only)
Unit: s
Setting range: OFF, 0.1 - 9.9
Factory setting: OFF
t-S t (time) - End: Final current duration (special 4-step mode only)
Unit: s
Setting range: OFF, 0.1 - 9.9
Factory setting: OFF
bbc burn-back time correction
Unit: ms
Setting range: 0 - 20
Factory setting: 0
IGC Ignition current
Unit: A
Setting range: 100 - 650
Factory setting: 500
Ito Ignition time-out function - Length of wire that is fed before the safety cut-out
is triggered
Unit: mm (in.)
Setting range: Off, 5 - 100 (Off, 0.2 - 3.94)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransSteel 5000 Rob and is the answer not in the manual?

Fronius TransSteel 5000 Rob Specifications

General IconGeneral
BrandFronius
ModelTransSteel 5000 Rob
CategoryPortable Generator
LanguageEnglish

Related product manuals