5. CONTROL SYSTEM
WIRELESS REMOTE CONTROLLER2-4.
MODEL : AR-RAH2E / AR-RAH1E

FEATURES

AR-RAH2E
AR-RAH1E
Built-in timers

Select from four different timer programs (ON/OFF/PROGRAM/SLEEP).
Program timer

The program timer operates the ON and OFF timer once within a 24 hour period.
Sleep timer

The sleep timer function automatically corrects the temperature thermostat setting according to the
time setting to prevent excessive cooling and heating while sleeping.
60min.
1°C
2°C
Timer setting
1°C
2°C
3°C
4°C
30min.
60min.
90min.
Timer setting
Cooling operation / dry operation
When the sleep timer is set, the set temperature
automatically rises 1°C every hour. The set
temperature can rise up to a maximum of 2°C.
Heating operation
When the sleep timer is set, the set temperature
automatically drops 1°C every 30 minutes. The set
temperature can drop to a maximum of 4°C.
Switching remote controller custom code

Code selector switch eliminates unit


being wrongly switched.
(Up to 4 custom codes can be set.)
*I.U.=Indoor unit
AB CD
AB
C
D
Mixed-up
I.U. I.U. I.U. I.U.
I.U. I.U. I.U. I.U.
After code change
Four kinds of timer setup available (ON/OFF/PROGRAM/SLEEP).îž”
Can be used jointly with wired remote controllers.îž”
Easy to change custom code (max. 4 custom codes).îž”
- (05 - 37) -
CONTROL
SYSTEM
CONTROL
SYSTEM

Table of Contents

Other manuals for Fujitsu ASYG07LMCA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG07LMCA and is the answer not in the manual?

Fujitsu ASYG07LMCA Specifications

General IconGeneral
BrandFujitsu
ModelASYG07LMCA
CategoryAir Conditioner
LanguageEnglish

Related product manuals