6. SYSTEM DESIGN
PRECAUTION
About fresh air intake kit
The Fresh Air Intake Kit can be installed onto cassette type air conditioners.
The volume of ventilated air provided by the Fresh Air Intake it a be unabe to u entiation
regulations in some countries.
On such occasions we ask that this kit be used along with Energy recovery ventilators.
When intaking outside air please ensure correct air-conditioning design based on air conditioning
load calculations.
As outside air is not being processed, an increase in outside air load can affect air conditioning.
Installation location
Area that generate substances that adversely affect the equipment, such as sulfuric
gas,chlorine gas,add,or alkali will cause the copper pipes and brazed joints to corrode, which
can cause refrigerant leakage.
Area with high salt content,such as at the seaside. It will deteriorate metal parts, causing the
parts to fall or the unit to leak water.
e certain to use eectric dapers and shutters to aoid intration o cod air wind and og
during shutdown in areas with cold climates, strong winds, or where fogs are common.
Please ensure the product is installed a distance of at least three times the duct diameter away
from exterior wall air inlets, or air exhausts for the prevention of short circuits.
Temperature conditions
Condensation may form on the product when outside air temperature is low, and the temperature
and humidity surrounding the product are high. Don't intake the air of below 0°
C
into the Fresh air
intake kit.
The upper Iimit of the product's temperature range should respond to the outdoor temperature
range.
About duct fan
When installing the duct fan, connect the drive relay ( ed suppied) and operate with the indoor
unit.
Please ensure the intake air volume is below 10% of the products air volume HI. When
the intaken air volume becomes too large there the operating noise may increase and room
temperature detection may be affected.
About the duct connection
Procure a duct with interna diaeter that ts the eterna diaeter o the duct ange.
Pease note that reguations o soe countries a reuire the use o a nonaabe duct.
 the duct penetrates a reretarding diision or other reproong easures the instaation
o re dapers or a construction that does not aderse aect re contro easures is a
regulatory requirement of some countries.
When using metallic ducts please ensure metals (i.e., metal lath, wire lath, stainless sheeting) are
eectrica insuated.  short circuit occurring b eectrica connection can cause re
Please ensure to thermally insulate connected ducts to prevent condensation.
Please make certain that netting or other measures are installed in parts exposed to the outside
air to preent intration o sa anias such as birds and insects.
Pease be certain to insta eterna air ters to parts eposed to the outside air or heat
exchanger protection of indoor equipment.
Pease aoid the intration o rain water b instaing outside ducts with an incine o at east 
and tting hoods on openings.
- (06 - 137) -
SYSTEM
DESIGN
SYSTEM
DESIGN

Table of Contents

Other manuals for Fujitsu ASYG07LMCA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG07LMCA and is the answer not in the manual?

Fujitsu ASYG07LMCA Specifications

General IconGeneral
BrandFujitsu
ModelASYG07LMCA
CategoryAir Conditioner
LanguageEnglish

Related product manuals