EasyManuals Logo
Home>Fujitsu>Server>PRIMERGY RX4770 M6

Fujitsu PRIMERGY RX4770 M6 User Manual

Fujitsu PRIMERGY RX4770 M6
468 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #127 background imageLoading...
Page #127 background image
CAUTION
Excessive temperatures could damage system components.
â–¶
Never leave the bay for the hot-plug PSU empty for more than two
minutes during operation.
If a hot-plug PSU should be removed from a redundant configuration,
while the system is in operation, proceed the following:
Disconnect the power cord from the dedicated PSU, see
"Disconnecting the power cord" on page 47.
A CSS error is detected and the message "redundancy lost" is displayed
using the iRMC web interface. Y
our configuration is now non-redundant.
The CSS error is only an information. After removing the PSU out of its
bay, the CSS error will be cleared automatically.
Installing the dummy cover
Figure 45: Installing the dummy cover
â–¶
Insert the dummy cover into the empty bay with the impressed arrow symbol
facing to the left (see circle).
â–¶
Push the dummy cover into its bay until it locks in place.
CAUTION
â–¶
Always install dummy covers into unused bays to comply with
applicable EMC regulations and satisfy cooling requirements.
Concluding steps
â–¶
No steps needed.
Power supply unit (PSU)
RX4770 M6 Upgrade and Maintenance Manual 127

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX4770 M6 and is the answer not in the manual?

Fujitsu PRIMERGY RX4770 M6 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX4770 M6
CategoryServer
LanguageEnglish

Related product manuals