CAUTION
Excessive temperatures could damage system components.
â–¶
Never leave the bay for the hot-plug PSU empty for more than two
minutes during operation.
If a hot-plug PSU should be removed from a redundant configuration,
while the system is in operation, proceed the following:
Disconnect the power cord from the dedicated PSU, see
"Disconnecting the power cord" on page 47.
A CSS error is detected and the message "redundancy lost" is displayed
using the iRMC web interface. Y
our configuration is now non-redundant.
The CSS error is only an information. After removing the PSU out of its
bay, the CSS error will be cleared automatically.
Installing the dummy cover
Figure 45: Installing the dummy cover
â–¶
Insert the dummy cover into the empty bay with the impressed arrow symbol
facing to the left (see circle).
â–¶
Push the dummy cover into its bay until it locks in place.
CAUTION
â–¶
Always install dummy covers into unused bays to comply with
applicable EMC regulations and satisfy cooling requirements.
Concluding steps
â–¶
No steps needed.
Power supply unit (PSU)