CAUTION
All data on all HDDs/SSDs in the array will be lost when deleting the
RAID array!
â–¶
Be sure to back up your data before deleting a RAID array.
â–¶
For more information, see the "ServerView Suite RAID
Management" user guide.
â–¶
If applicable,"Removing the front cover with lock" on page 45
.
Removing a 2.5-inch HDD/SSD module
â–¶
Pinch the green locking clips and open the locking lever (see Figure 59).
â–¶
Pull the HDD/SSD module out a few centimeters.
â–¶
Wait about 30 seconds.
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
This period is necessary for the RAID controller to recognize that an
SSD module has been removed.
â–¶
Pull the HDD/SSD module completely out of its bay
.
Installing a 2.5-inch dummy module
CAUTION
â–¶
If the removed HDD/SSD module is not replaced immediately,
always replace a dummy module into the unused HDD/SSD bay to
comply with applicable EMC regulations and satisfy cooling
requirements.
Hard disk drive (HDD) / solid state disk (SSD)
146 Upgrade and Maintenance Manual RX4770 M6