1. MOUNTING
1-9
1.2.2 Flush mounting (optional)
You can use the optional FM FIXTURE ASSEMBLY kit (OP24-38) to flush-mount the
unit.
Type: OP24-38, Code No.: 001-263-190
Note: The flush mount location must have a thickness of at least 10 mm, with a max-
imum thickness of 20 mm.
1. Referring the outline drawing at the back of the manual, mark and cut a hole in the
position you wish to locate the unit.
2. Set the USB cable through the hole, then place the unit inside the hole.
3. Attach two FM (flush mount) fixture assembly to the unit’s under side using four
washer head screws (M410), both included in the kit.
4. Fasten the wingbolts until the footing is flush against the mounting area.
5. Tighten the wingnuts until the unit is firmly secured.
Name Type Qty
FM Fixture Assembly OP24-38-1 2
Washer Head Screw M410 4
Console (Underside)
FM fixture assembly
Footings are flush against
the mounting area
Wingnut
Wingbolt