2. WIRING
2-7
2.1.5 Fabricating JIS cables
Fabricate JIS cables as shown below to connect them to the WAGO connectors on
the PCU-3000 (See following page for WAGO connection).
After fabricating the cable, attach the WAGO connector and EMI ferrite core (sup-
plied). For how to attach the WAGO connecor and EMI ferrite core, see the next page.
Shield
6
5
100
*
30
Armor
Sheath
200
Fabrication of TTYCS series
Vinyl tape (Width: 20)
After exposing cores, wind shield
around the armor.
Clamp here with cable clamp.
Fabrication of TTYCSLA series
Pass a heat shrink tube (local supply) onto the
drain wire, then attach the crimp-on lug (supplied
with the PCU-3000) to it.
Sheath
Armor
Vinyl tape (Width: 20)
Clamp here with cable clamp.
Drain wire
Crimp-on lug (supplied)
80
150
6
NOTE: All dimension in millimeters
LAN2 LAN1
USB2
USB1
USB4
USB3
For flush mounted
installations, connect the
drain wire to this terminal.
C1
C2C4
C3
IEC61162-1/2