SYSTEM CONFIGURATION
iii
Multiple workstations (Maximum 3)
When displaying images on MU-270W from FMD-3100 via external output (DVI)
• When the [DISP MODE] of MU-270W is [FULL].
Full HD images are expanded and displayed in full-screen on the MU-270W.
• When the [DISP MODE] of MU-270W is [NORMAL].
Full HD images are displayed on the screen of the MU-270W but not expanded.
(Top and bottom of the screen are displayed as black bars.)
Dashed lines indicate
optional or local supply
equipment.
Category of units
All units protected
from the weather.
Gateway network
equipment
(radar, ECDIS, etc.)
Trackball Control Unit
RCU-030
Keyboard
5139U (Black)
USB DVD Drive
USB Printer,
USB Flash Drive
Serial Interface (4 ports):
• IEC 61162-1/2x2 (AIS, GYRO)
• IEC 61162-1x2 (GPS, LOG)
100-230VAC
24VDC
Switching Hub
HUB-100
Sensor Adapter
MC-3020D
Sensor Adapter
MC-3030D
Serial interface
Digital IN interface
Digital OUT interface
Sensor Adapter
MC-3000S
PANEL
COMPUTER
UNIT
PCU-3000
PANEL
COMPUTER
UNIT
PCU-3000
Same equip-
ment as
shown left.
100-230 VAC
or
24 VDC
100-230 VAC
or
24 VDC
Intelligent Hub
HUB-3000
100-230 VAC
100-115/200-230 VAC
1Ø, 50/60 Hz
24 VDC
Radar 1
Radar Connection Box
RCB-002
AC/DC Power
Supply Unit
PR-240
Radar 2
External Monitor*
1
, VDR*
2
*
1
Use full HD monitor or better.
*
2
ECDIS picture data can be
sent periodically to a VDR via
LAN. Connect the VDR to the
LAN2 port on the Panel PC to