2. WIRING
2-2
Wiring considerations
Network and sensor considerations
USB cable lengths should be within 5 m, with or without the USB extension cable. Full
function cannot be guaranteed if the overall USB length exceeds 5 m.
The PCU-3000 is not compatible with the USB 3.0 equipments.
USB cables should be secured using the clamp highlighted in the figure below.
LAN cable lengths between units should be within 50 m.
The DVI-D port outputs FULL HD resolution. Make sure the cables connected to the
DVI-D port are 5 m or less.
If extension or division of the DVI or ERGB cables is required, use the dividers listed
below:
DVI cable divider: D8013F (maker: IMAGENICS)
RGB divider: CIF-12H, DD-106 or D8013F (maker: IMAGENICS)
Ensure all grounding wires are connected between grounding terminals on each
equipment and ship earth.
If a UPS (user supply) is connected to this equipment, ensure the grounding lamp
does not light up.
Use the following LAN cables for the network if they are available locally.
Sensor Network: Cat5 or better.
Gateway Network: Cat5e or better.
If LAN cables are not available locally, use the optional LAN cables as below:
Sensor network - FR-FTPC-CY (Cat5 equivalent).
Gateway network - DTI-C5E350 VCV (Cat5e equivalent).
ECDIS control unit RCU-024 and RCU-026 are not compatible with this equipment.
When connecting this equipment to a VR-3000/S, use the DVI-I port. The DVI-I port
outputs FULL HD resolution and requires a synchronizer to convert the output to
UXGA.
When connecting a VDR device via LAN, connect the VDR device to the LAN2 port.
For Sensor network construction, use the optional Switching Hub HUB-100.
For Gateway network construction use the optional Intelligent Hub HUB-3000.
Do not connect the vessel’s on-board LAN to either of the above networks. Also,
commercial PCs cannot be connected to the gateway network, other than for
maintenance.
Connect to other ECDIS units and radars (FEA-2xx7 or FAR-2xx7 series radars)
using the gateway network.
When constructing a network with two or more FAR-2xx7 radars, an FMD-3x00 unit
and using a HUB-3000, the HUB-3000 querier must be configured. To configure the
querier, consult with a Furuno engineer.
The FMD-3100 processor unit does not support IGMP snooping or CGMP enabled
switch.
The FMD-3100 does not have a router or repeater hub function.
The Switching Hub HUB-100 is optionally available for connection to the FMD-3100.
The Switching HUB HUB-100 does not support IGMP snooping or GCMP enabled
switch.
When you use IEC61162-450 compatible sensors, set [Transmission Group] on the
[Common Installation Settings] menu. Only service technicians can access the
[Common Installation Settings] menu. Contact your FURUNO dealer to set it.
Cable clamp for USB cables