EasyManuals Logo
Home>FUTABA>Remote Control>T18MZ

FUTABA T18MZ User Manual

FUTABA T18MZ
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #77 background imageLoading...
Page #77 background image
77
<Linkage Menu>
System Type selection

changed from among 5 choices: FASSTest 18CH,

S-FHSS. Select the system matched to the type of
receiver you are using.u
*Even if it changes a System Type, other model data is not
reset.e
*If a system type is changed in the case of a helicopter, It
can choose out of two channel orders.
[Yes] : Selection sets the channel order suitable for System
Type. (We recommend here. )
[No] : The present channel order is maintained.
*After change should operate a model and should fully
check a direction and a motion.
Receiver linking
The receiver will only be controlled (without being
affected by other transmitters) by the transmitter it
is linked to. When using a receiver other than one
purchased as a set, linking is necessary.
Dual receiver function (only FASSTest 18CH
mode)
Dual receivers can be linked with the T18MZ.
Two receivers are recognized individually by ID


"1-8CH", and setting the second as "9-16CH", two
sets of receivers can be used as a set in the model,
allowing you 16 channels. If a Dual receiver
function is used, the following function can set up
individually.

Telemetry function
Sensor setup



System Type

Telemetry function (FASSTest mode only)
To use the telemetry function, set “Telemetry” to
“ON”.
D/L Interval (FASSTest mode only)
When a telemetry function is enabled, the receiving
interval (down-link interval) of sensor data can be
changed.

the sensor data display becomes slower, but stick
response will improve.
Battery fail-safe voltage setup (only FASSTest
mode)
The voltage which battery fail-safe activates, can

memorizes the setting as it was at link.
Suggested setting voltages are as follows.



It is a rough reference value.
Since it changes with servos carried in the
condition and the model of a battery, please set to
your own model in a battery consumption current.

Table of Contents

Other manuals for FUTABA T18MZ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FUTABA T18MZ and is the answer not in the manual?

FUTABA T18MZ Specifications

General IconGeneral
BrandFUTABA
ModelT18MZ
CategoryRemote Control
LanguageEnglish

Related product manuals