7.7 Security Codes Menu
The security code for entry into the Operators Program is factory set so that the
operator presses button 1 on the service keypad followed by the sequence 2-2-2-2
on the drink selection keypad. On no account should this code be altered without
first consulting your supervisor or manager.
7.8 Timed Events Menu
7.8.1 Time of Day Events
From this menu the operator can set up inhibited vend periods, free vend
periods and discounted vend periods.
The following example describes how the operator can program the machine
to free vend specific drink selections between 10.30 am and 2:30 pm on week
days.
1. From the Main Menu press the ▼ (down)
key until Timed Events is highlighted then
press the ↵ (Edit) key twice to access the
Time of Day menu screen. The LCD will
display the screen as shown.
N.B. Although event 1 is shown as Inhibit, it is possible for the operator
to set event 1 as the first Free Vend (or Discounted Vend) period.
2. Press the ↵ (Edit) key to access the menu.
The LCD will display the screen as shown.
By default the current State is set to Off
as indicated by the status line at the
bottom of the screen.
3. Press the ↵ (Edit) key to access the State
sub menu. Using the
▼ (down) key, set
the state to On (indicated by the filled
radio button). Press the ↵ (Edit) key to
return to the Event 1 screen. Verify that
the status line confirms the State is set to
On.
4. Press the
▼ (down) key to highlight Event
Type and press the ↵ (Edit) key to access
the menu. Using the
▼ (down) key, set the
Event Type to Free Vend (indicated by the
filled radio button). Press the ↵ (Edit) key
to return to the Event 1 screen. Verify
that the status line confirms the Event Type is set to Free Vend.
52