Configuring GWN7000 IPSec Tunnel
In order to build an IPSec secure tunnel between two devices located on different places on the Internet,
we can use the sample scenario below:
Branch office router needs to connect to Headquarters office via an IPSec tunnel, on each side we have a
GWN7000 router. Users can configure the two devices as following:
The branch office router runs a LAN subnet 192.168.1.0/24 and the HQ router runs a LAN subnet
192.168.3.0, the public IP of the branch office router is 1.1.1.1 and the IP of the HQ router is 2.2.2.2.
Configuration of Branch office router:
Go under VPN → IPSec then click on add and fill in the following information under phase 1 tab: