Save These Instructions3-90-775R36_09/15
D.BeforeYourFirstFire
Be sure the appliance is installed properly and that
all safety requirements have been met. Pay particular
attention to the clearances to combustibles, oor
protection and the venting instructions.
Testyour smoke detector(s)andCO detector(s) tothe
specicationsofthemanufacturer.
Doublecheckthattheashpanandinternalreboxare
empty.
Be sure to read this entire manual.
E.DraftTestProcedure
Usinga9/16"wrench,removethedrafttestportplugbolt,
located to the left inside the rebox. This bolt threads
downward through the outside of the body. Externally,
the opened hole is located above the ash pan spring
latch on the left.
Insert the draft meter hose into the test port.
Be sure the meter is capable of a scale between 0 and
1inchWaterColumn.Zerothemeterifnecessary,and
be sure it is set up to read in negative pressure.
Be sure the ash pan, door, and hopper lid are all closed
and latched.
Turn the Feed Limit dial to "Test" mode.
During the rst minute of test, the combustion blower
will be on high. Record the high draft reading here
____________-W.C. The high draft should be above
-0.5"W.C.butnohigherthan-1"W.C.
After a minute, the combustion blower will go to low
speed.Hereyouwanttoseeareadingbetween-0.30"
and -0.35". If necessary, adjust the draftvoltage using
the low draft adjustment screw on the circuit board (See
Page24).Clockwisewillincreasethedraftandcounter-
clockwisewilldecreaseit.
Onceset,recordthelowdraftreadinghere:___________
-W.C.
Be sure and turn off of "Test" mode. Disconnect the
meter and return the plug bolt to the test port.
The optimal method of operation is in Room Temp
mode, with the Ignition switch set to Automatic.
TESTED AND APPROVED FOR USE WITH WOOD
PELLETS ONLY. USE OF ANY OTHER TYPE OF FUEL
WILL VOID THE APPLIANCE WARRANTY.
WARNING
!
"NEVER USE GASOLINE, GASOLINE-TYPE
LANTERNFUEL,KEROSENE,CHARCOAL
LIGHTER FLUID, OR SIMILAR LIQUIDS TO
START OR "FRESHEN UP " A FIRE IN THIS
HEATER.KEEPALLSUCHLIQUIDSWELL
AWAY FROM THE HEATER WHILE IN USE".
WARNING
!
DRAFT BOLT

Table of Contents

Other manuals for Harman P35I

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Harman P35I and is the answer not in the manual?

Harman P35I Specifications

General IconGeneral
BrandHarman
ModelP35I
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals