26
Save These Instructions3-90-775R36_09/15
D.BeforeYourFirstFire
• Be sure the appliance is installed properly and that
all safety requirements have been met. Pay particular
attention to the clearances to combustibles, oor
protection and the venting instructions.
• Testyour smoke detector(s)andCO detector(s) tothe
specicationsofthemanufacturer.
• Doublecheckthattheashpanandinternalreboxare
empty.
• Be sure to read this entire manual.
E.DraftTestProcedure
• Usinga9/16"wrench,removethedrafttestportplugbolt,
located to the left inside the rebox. This bolt threads
downward through the outside of the body. Externally,
the opened hole is located above the ash pan spring
latch on the left.
• Insert the draft meter hose into the test port.
• Be sure the meter is capable of a scale between 0 and
1inchWaterColumn.Zerothemeterifnecessary,and
be sure it is set up to read in negative pressure.
• Be sure the ash pan, door, and hopper lid are all closed
and latched.
• Turn the Feed Limit dial to "Test" mode.
• During the rst minute of test, the combustion blower
will be on high. Record the high draft reading here
____________-W.C. The high draft should be above
-0.5"W.C.butnohigherthan-1"W.C.
• After a minute, the combustion blower will go to low
speed.Hereyouwanttoseeareadingbetween-0.30"
and -0.35". If necessary, adjust the draftvoltage using
the low draft adjustment screw on the circuit board (See
Page24).Clockwisewillincreasethedraftandcounter-
clockwisewilldecreaseit.
• Onceset,recordthelowdraftreadinghere:___________
-W.C.
• Be sure and turn off of "Test" mode. Disconnect the
meter and return the plug bolt to the test port.
The optimal method of operation is in Room Temp
mode, with the Ignition switch set to Automatic.
TESTED AND APPROVED FOR USE WITH WOOD
PELLETS ONLY. USE OF ANY OTHER TYPE OF FUEL
WILL VOID THE APPLIANCE WARRANTY.
WARNING
"NEVER USE GASOLINE, GASOLINE-TYPE
LANTERNFUEL,KEROSENE,CHARCOAL
LIGHTER FLUID, OR SIMILAR LIQUIDS TO
START OR "FRESHEN UP " A FIRE IN THIS
HEATER.KEEPALLSUCHLIQUIDSWELL
AWAY FROM THE HEATER WHILE IN USE".
WARNING
DRAFT BOLT