39
Save These Instructions 3-90-775R36_09/15
B.LossofPower
MinimizingSmokeDuringLossofPowerUsingBattery
Back-up
Harman® strongly recommends installing battery back-
up to minimize entry of smoke into the room in the
eventofpowerloss.
Your pellet/biomass burning appliance relies on a
combustionblowertoremoveexhaust.Apowerfailurewill
cause the combustion blower to stop. This may lead to
exhaustseepingintotheroom.Verticalriseintheventing
may provide natural draft. It is, however, no guarantee
againstleakage.
There are two Harman® approved battery back-up
optionsforyourappliance:
Uninterruptible Power Supply UPSbatteryback-upsare
availableonlineoratcomputerandofceequipmentstores.
Your Harman® appliance with Rev E or later software
available beginning in November 2010 may be plugged
directly into a Harman® approved UPS:
• The APC (American Power Conversion) model
#BE750G and the TrippLite model INTERNET750U are
testedandapproved.Otherbrandsormodelsmaynot
be compatible.
Whenpowerislost,afullychargedUPSwillpowerasafe,
combustion blower only shut-down. Your appliance will
pulsetheblowereveryfewsecondstoclearexhaustuntil
thereisout.NOTE:TheUPSprovidessafeshut-down
only.Itisnotintendedforcontinuedoperation.
• TheSurere512connectstoa12voltdeepcyclebattery
thatwillrunyourappliance for upto eight(8) hours.It
includesatricklechargefeaturethatkeepsyourbattery
chargedwhenpowerisavailable.NOTE:Ifthepoweris
outforlongerthanbatterylife,smokeleakagemaystill
occur unless your stove has been safely shut down.
Yourappliancewillrecognizewhenpowerisrestored.What
happens depends on ESP temperature and whether it is
equipped with automatic ignition:
• In “Automatic” Mode, units equipped with automatic
ignition will respond to the set point and ESP temperature
and resume normal operation.
• In “Idle” Mode, or for units without automatic ignition:
• If the ESP is cool, the appliance will remain shut
down.
• IfthereisoutandtheESPisstillwarm,thefeeder
mayrestart.Sincethereisout,theESPtemperature
willnotrise.Theunitwillthenshut-down,andmay
ashasix-blinkstatuserror.(SeeESPerrorcodes)
• If the re is still burning, it will resume normal
operation.
Contact your dealer if you have questions about UPS
compatibility with your appliance.
Use only Harman
®
approved battery back-up devices.
Other products may not operate properly, can create
unsafeconditionsordamageyourappliance.
CAUTION
Always keep appliance doors and hopper lid closed
and latched during operation and during power
failurestominimizeriskofsmokeorburn-back.
C. Emergency Manual Ignition
Harman
®
pellet stoves and inserts should be lit using the
automatic ignition system. This is the safest and most
reliable way for igniting the unit. In the event the automatic
igniter is not functioning, the steps below may be followed
tomanuallylightthestoveorinsertinthe“ConstantBurn”
mode. Manual lighting is for emergency purposes only,
and the igniter should be repaired or replaced as soon as
practical.
WARNING
Only use restarter commercially marketed for pellet
stoves and inserts, including wax coated wood chips,
pellet starter gel and pellet igniter blocks. Use of any
othertypeofrestarterisprohibited.
To avoid serious injury or death read and follow
manufacturer’swarningandinstructionsforuseofrestarter.
Useofrestarterisonlypermittedwhenperformingacold
start.
Never attempt to manually light a stove or insert that has
been operated recently and is not at room temperature.
If automatic ignition was attempted, be sure to give the
stove or insert at least 30 minutes or longer to cool to room
temperature.
Besurethatthestoveorinsertisinthe“Igniter-Disabled”
mode of operation.
Once all the precautions have been taken, follow these
steps:
1.TurntheModeSelectorto“OFF”.
2.Fillburnpotwithpellets,onlyhalfway.(DoNotOverFill).
3. Add firestarter to pellets following manufacturer’s
instructions.
4. Light pellet gel with a match, and close the door, turn Mode
SelectortoConstantBurn.Operationwillbeginwhenthe
rereachesthepropertemperature.
WARNING