Save These Instructions 3-90-775R36_09/15
B.LossofPower
MinimizingSmokeDuringLossofPowerUsingBattery
Back-up
Harman® strongly recommends installing battery back-
up to minimize entry of smoke into the room in the
eventofpowerloss.
Your pellet/biomass burning appliance relies on a
combustionblowertoremoveexhaust.Apowerfailurewill
cause the combustion blower to stop. This may lead to
exhaustseepingintotheroom.Verticalriseintheventing
may provide natural draft. It is, however, no guarantee
againstleakage.
There are two Harman® approved battery back-up
optionsforyourappliance:
Uninterruptible Power Supply UPSbatteryback-upsare
availableonlineoratcomputerandofceequipmentstores.
Your Harman® appliance with Rev E or later software
available beginning in November 2010 may be plugged
directly into a Harman® approved UPS:
• The APC (American Power Conversion) model
#BE750G and the TrippLite model INTERNET750U are
testedandapproved.Otherbrandsormodelsmaynot
be compatible.
Whenpowerislost,afullychargedUPSwillpowerasafe,
combustion blower only shut-down. Your appliance will
pulsetheblowereveryfewsecondstoclearexhaustuntil
thereisout.NOTE:TheUPSprovidessafeshut-down
only.Itisnotintendedforcontinuedoperation.
• TheSurere512connectstoa12voltdeepcyclebattery
thatwillrunyourappliance for upto eight(8) hours.It
includesatricklechargefeaturethatkeepsyourbattery
chargedwhenpowerisavailable.NOTE:Ifthepoweris
outforlongerthanbatterylife,smokeleakagemaystill
occur unless your stove has been safely shut down.
Yourappliancewillrecognizewhenpowerisrestored.What
happens depends on ESP temperature and whether it is
equipped with automatic ignition:
In “Automatic” Mode, units equipped with automatic
ignition will respond to the set point and ESP temperature
and resume normal operation.
In “Idle” Mode, or for units without automatic ignition:
If the ESP is cool, the appliance will remain shut
down.
• IfthereisoutandtheESPisstillwarm,thefeeder
mayrestart.Sincethereisout,theESPtemperature
willnotrise.Theunitwillthenshut-down,andmay
ashasix-blinkstatuserror.(SeeESPerrorcodes)
• If the re is still burning, it will resume normal
operation.
Contact your dealer if you have questions about UPS
compatibility with your appliance.
Use only Harman
®
approved battery back-up devices.
Other products may not operate properly, can create
unsafeconditionsordamageyourappliance.
CAUTION
!
Always keep appliance doors and hopper lid closed
and latched during operation and during power
failurestominimizeriskofsmokeorburn-back.
C. Emergency Manual Ignition
Harman
®
pellet stoves and inserts should be lit using the
automatic ignition system. This is the safest and most
reliable way for igniting the unit. In the event the automatic
igniter is not functioning, the steps below may be followed
tomanuallylightthestoveorinsertinthe“ConstantBurn”
mode. Manual lighting is for emergency purposes only,
and the igniter should be repaired or replaced as soon as
practical.
WARNING
!
Only use restarter commercially marketed for pellet
stoves and inserts, including wax coated wood chips,
pellet starter gel and pellet igniter blocks. Use of any
othertypeofrestarterisprohibited.
To avoid serious injury or death read and follow
manufacturer’swarningandinstructionsforuseofrestarter.
Useofrestarterisonlypermittedwhenperformingacold
start.
Never attempt to manually light a stove or insert that has
been operated recently and is not at room temperature.
If automatic ignition was attempted, be sure to give the
stove or insert at least 30 minutes or longer to cool to room
temperature.
Besurethatthestoveorinsertisinthe“Igniter-Disabled”
mode of operation.
Once all the precautions have been taken, follow these
steps:
1.TurntheModeSelectorto“OFF”.
2.Fillburnpotwithpellets,onlyhalfway.(DoNotOverFill).
3. Add firestarter to pellets following manufacturer’s
instructions.
4. Light pellet gel with a match, and close the door, turn Mode
SelectortoConstantBurn.Operationwillbeginwhenthe
rereachesthepropertemperature.
WARNING
!

Table of Contents

Other manuals for Harman P35I

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Harman P35I and is the answer not in the manual?

Harman P35I Specifications

General IconGeneral
BrandHarman
ModelP35I
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals