Save These Instructions 3-90-775R36_09/15
A. Shut-down Procedure
The best way to shut down the appliance is to simply let it
run out of fuel, and shut down naturally as the temperature
cools. This method is highly recommended for the end of
seasonshut-down.
To shut-down otherwise, turn the mode selector to "OFF'
verifybyensuringthattheStatuslightgoesout.Theshut-
downprotocolofthecircuitboardwillsafelyallowthereto
goout.Allmotorswillstopwhencool,andonlythePOWER
light will remain lit. It is now safe to unplug the electrical
supply.
CAUTION! SHOCK AND SMOKE HAZARD!
ProperShut-downproceduremustbefollowed.
Smokespillagemayoccurifshut-downisnotcomplete.
Riskofshockifapplianceisnotdisconnectedfromthe
supply power prior to servicing.
Cleaning or Inspection Frequency
Daily Weekly Monthly Yearly
Areabeneathburnpotgrate/
Igniter After each ton of fuel burned
OR X
Ash removal Depending on fuel quality
OR X X
Burn pot grate surface Depending on fuel quality
OR X
Combustionblower/paddlefan After each ton of fuel burned
OR X
Distribution blower
More frequently depending on
surroundings
OR X
Door latch inspection Prior to heating season
OR X
Feederbody/Finescollection
area Depending on fuel quality
OR X
Firebox/thoroughcleaning After each ton of fuel burned
OR X
Glass
Whenviewofrebecomes
obstructed
OR X
Heatexchanger After each ton of fuel burned
OR X
Hopper Wheneveraddingfuel
OR X
Venting system
More frequently depending on
fuel quality and quantity
OR X
Soot- Formation and Need For Removal-Whenwoodis
burned, the products of combustion combine with moisture
toformasootresiduewhichaccumulatesontheuelining.
When ignited, this soot makes an extremely hot re.The
entire venting system should be inspected at least once
every two months during the heating season to determine
if a soot buildup has occurred. If soot has accumulated, it
shouldberemovedtoreducetheriskofachimneyre.
Ifyouexperienceachimneyre;Turnthecontrolto"Off".
Keep appliance doors and hopper lid closed and latched.
Notify the re department. Do not operate the appliance
until the chimney and connector have been inspected and
approved by a chimney professional.
B.QuickReferenceMaintenanceChart
Follow the detailed instructions found in this section for each point listed in the chart below.
NOTICE:Forrecommendationpurposesonly-Morefrequentcleaningisnecessaryifheavybuildupisencounteredatthe
recommended intervals, or if you see soot coming from the vent. Failure to clean your appliance on a regular basis will
void the product warranty.
11
Service & Maintenance

Table of Contents

Other manuals for Harman P35I

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Harman P35I and is the answer not in the manual?

Harman P35I Specifications

General IconGeneral
BrandHarman
ModelP35I
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals