Chapter 5 Cable and Transmission Distance
Cable and transmission distance between devices should follow rules below.
Table 5-1 Cable and Transmission Distance
Cable
Type
DS-
KAD7061
to DS-
KAD7061
DS-
KAD7061
to Main
Indoor
Staon
Indoor
Staon to
Indoor
Staon
DS-
KAD7061
to DS-
KAD7060
DS-
KAD7060
to Power
Module/
KAD-7060-
S
DS-
KAD7060
to Door
Staon
Door
Staon to
Lock
(Power
Supply)
UTP 5 0.2
mm
2
(Cat.
5) AWG24
60 m 60 m 60 m 60 m 100 m 60 m NA
0.28 mm
2
(TP)
AWG23
60 m 40 m 40 m 40 m 80 m 40 m 30 m
0.5 mm
2
(Parallel)
AWG20
60 m 60 m 60 m 60 m 100 m 60 m 50 m
1 mm
2
(Parallel)
AWG17
60 m 60 m 60 m 60 m 100 m 60 m 50 m
1 mm
2
(TP)
AWG17
60 m 40 m 40 m 40 m 80 m 40 m 100 m
1 mm
2
(Parallel)
AWG15
60 m 40 m 60 m 60 m 100 m 60 m 100 m
Note
Distance from power supply to the furthest indoor staon is 200 m.