Event Output
Select the output to show the event video.
Full Screen Monitoring Dwell Time
Set the me in seconds to show the alarm event screen. If alarms are triggered
simultaneously in several channels, their full-screen images will be switched at an interval of
10 seconds (default dwell me).
3. Go to the Linkage Acon interface of the alarm detecon (e.g., moon detecon, video
tampering, face detecon, etc.).
4. Select the Full Screen Monitoring alarm linkage
acon.
5. Select the channel(s) in Trigger Channel for full screen monitoring.
6.4.2
Congure Buzzer
When an alarm is detected, the buzzer will make an audible beep.
Steps
1. Go to System → Live View → General .
2. Check Enable Audio Output.
3. Set the audio volume.
4. Click Apply.
5. Go to Linkage
Acon interface of the alarm detecon (e.g., moon detecon, video tampering,
face detecon, etc.).
6. Select Buzzer as the alarm linkage
acon.
6.4.3
Nofy Surveillance Center
The device can send an excepon or alarm signal to the remote alarm host when an event occurs.
The alarm host refers to the PC installed with client
soware (e.g., iVMS-4200, iVMS-5200).
Steps
1. Go to System → Network → Advanced → More Sengs .
2. Set the alarm host IP and alarm host port.
3. Go to Linkage
Acon interface of the alarm detecon (e.g., moon detecon, video tampering,
face detecon, etc.).
4. Select
Nofy Surveillance Center.
6.4.4
Congure Email Linkage
The system can send an email with alarm informaon to a user or users when an alarm is detected.
Steps
1. Go to System → Network → Advanced → Email .
2. Set the email parameters.
Network Video Recorder User Manual
77