9-7 On-screen message descriptions
9.2.2 Warning messages
No. Message Meaning of message Remedy
65
Excitation V-ref.
Review
The difference between the ambient
temperature and the standard ambient
temperature exceeded a fixed value.
Perform nozzle test and
update the excitation V-ref.
setting.
( Technical manual 6.10)
66
Viscosity Reading
Instability
Measurement results of viscometer vary.
Contact your nearest local
distributor.
67
Viscosity
Readings Out of
Range
Viscometer does not function normally.
Contact your nearest local
distributor.
68 High Ink Viscosity Ink viscosity is high.
Ink viscosity is now adjusted
to normal level.
If print quality is still poor,
replace ink with a new one.
( Technical manual 6.3)
69 Low Ink Viscosity Ink viscosity is low.
. Ink viscosity is now adjusted
to normal level.
If print quality is still poor,
replace ink with a new one.
( Technical manual 6.3)
71 Battery Low M
The engine section built-in battery voltage
is too low.
Contact your nearest local
distributor.
When making prints, set the
correct calendar time again
from the date/time setup
screen ( 6.2).
72
Calendar Content
Inaccurate
Calendar print contents are not accurate
due to faulty built-in battery.
Contact your nearest local
distributor.
75
External
Communication
Error nnn
The external communication function is not
normally exercised.
Note the error code and see
that no more errors occur.
81 Ink Low Warning The ink level in the ink reservoir is too low.
Add ink within 60 minutes
( 8.1).
82
Makeup Low
Warning
The makeup level in the makeup reservoir
is too low.
Add the makeup within 60
minutes.
( 8.2).
83
Ink Shelf Life
Exceeded
The cumulative ink ejection time exceeded
the preselected alarm time.
Replace the ink
( Technical manual 6.3).
84
Ambient
Temperature Too
High
The ambient temperature is higher than the
upper-limit operating temperature.
Ensure that the ambient
temperature is within the
operating temperature limits.
85
Ambient
Temperature Too
Low
The ambient temperature is lower than the
lower-limit operating temperature.
Ensure that the ambient tem-
perature is within the operat-
ing temperature limits.