Installation SmartRadar FlexLine
Installation Guide Part No.: 4417.760_Rev06
36
4.11.3.5.1 FII-DO
4.11.3.5.2 FII-DO - Overfill Protection
4.11.3.6 HCI-HAO
Label Parameters
14. Ry1_a Vmax = 125 Vac, Imax = 0.5 A
Vmax = 110 Vdc, Imax = 0.3 A
Pmax = 30 W
NO/NC by factory jumper
15. Ry1_b
16. Ry2_a Vmax = 125 Vac, Imax = 0.5 A
Vmax = 110 Vdc, Imax = 0.3 A
Pmax = 30 W
NO/NC by factory jumper (default = NO)
17. Ry2_b
18. Ry3_a Vmax = 250 Vac, Imax = 3 A
Vmax = 40 Vdc, Imax = 3 A
Pmax = 750 W
NO/NC by factory jumper
19. Ry3_b
20. Ry4_a Vmax = 250 Vac, Imax = 3 A
Vmax = 40 Vdc, Imax = 3 A
Pmax = 750 W
NO/NC by factory jumper
21. Ry4_b
Label Parameters
48. Ofp_a Vmax = 250 Vac, Imax = 3 A
Vmax = 40 Vdc, Imax = 3 A
Pmax = 750 W
NO/NC by factory jumper
49. Ofp_b
Cable specifications
Type Shielded twisted pair
Maximum length 1200 meter
Label Parameters
46. 4-20 mA +
47. 4-20 mA -