6 - 36
MicroPDF417
< Default All MicroPDF417 Settings >
MicroPDF417 On/Off
MicroPDF417 Message Length
Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional
information. Minimum and Maximum lengths = 1-366. Minimum Default = 1, Maximum Default = 366.
GS1 Composite Codes
Linear codes are combined with a unique 2D composite component to form a new class called GS1 Composite symbology.
GS1 Composite symbologies allow for the co-existence of symbologies already in use. Default = Off.
On
* Off
Minimum Message Length
Maximum Message Length
On
* Off

Table of Contents

Other manuals for Honeywell Genesis 7580G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Genesis 7580G and is the answer not in the manual?

Honeywell Genesis 7580G Specifications

General IconGeneral
TypeFixed bar code reader
Sensor type-
Scanner type1D/2D
Pitch reading angle-70 - 70 °
Motion tolerance (cm/s)200
Light levels (direct sunlight)0 - 100000 lx
Standard interfacesUSB, RS-232, RS-485, Keyboard wedge
Product colorBlack, Silver
Input voltage5.5 V
Power consumption (standby)0.5 W
Power consumption (typical)2 W
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)0 - 95 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth80 mm
Width83 mm
Height150 mm
Weight340 g