EasyManuals Logo
Home>Honeywell>Barcode Reader>Genesis 7580G

Honeywell Genesis 7580G User Manual

Honeywell Genesis 7580G
202 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
3 - 7
Presentation LED Behavior after Decode
When a scanner is in presentation mode, the LEDs dim 30 seconds after a bar code is decoded. If you wish to dim the
LEDs immediately after a bar code is decoded, scan the LEDs Off bar code, below. Default = LEDs On.
Presentation Sensitivity
Presentation Sensitivity is a numeric range that increases or decreases the scanner's reaction time to bar code presenta-
tion. To set the sensitivity, scan the Sensitivity bar code, then scan the degree of sensitivity (from 0-20) from the inside
back cover, and Save. 0 is the most sensitive setting, and 20 is the least sensitive. Default = 1.o
Presentation Centering
Use Presentation Centering to narrow the scanner’s field of view when it is in Presentation Mode to make sure the scanner
reads only those bar codes intended by the user. For instance, if multiple codes are placed closely together, Presentation
Centering will insure that only the desired codes are read.
Note: To adjust centering when the scanner is hand-held, see Presentation Aimer Mode (page 3-12).
If a bar code is not touched by a predefined window, it will not be decoded or output by the scanner. If Presentation Center-
ing is turned on by scanning Presentation Centering On, the scanner only reads codes that pass through the centering
window you specify using the Top of Presentation Centering Window, Bottom of Presentation Centering Window,
Left, and Right of Presentation Centering Window bar codes.
* LEDs On
LEDs Off
Sensitivity

Table of Contents

Other manuals for Honeywell Genesis 7580G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Genesis 7580G and is the answer not in the manual?

Honeywell Genesis 7580G Specifications

General IconGeneral
TypeFixed bar code reader
Sensor type-
Scanner type1D/2D
Pitch reading angle-70 - 70 °
Motion tolerance (cm/s)200
Light levels (direct sunlight)0 - 100000 lx
Standard interfacesUSB, RS-232, RS-485, Keyboard wedge
Product colorBlack, Silver
Input voltage5.5 V
Power consumption (standby)0.5 W
Power consumption (typical)2 W
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)0 - 95 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth80 mm
Width83 mm
Height150 mm
Weight340 g