EasyManuals Logo
Home>HP>Cash Counter>5315 A

HP 5315 A User Manual

HP 5315 A
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
Model
5315A/ 8
Ope
r
at
ion
3·10
3-52. ERROR MESSAGES
53
. f ailur
es
du
ring the po
wer
·
up
self·check
rout
i
ne
w
il
l result
in
a (
mome
ntary) displ
ay
of
a
n
um
b
ered
e
rr
or
message. In ad
di
tio
n,
the
ERROR an
nun
ciator
will
lig
ht
and remain
li
t u
nt
il
the
error
is
cleared and
the
instru
ment
r
es
ta
rt
ed. T
here
are three numb
ered
Error Messages, as
listed b
elow:
ERROR MESSAGE
E1
..............
.
Poss
ible
fa
ilure
in
M i
croco
m
pute
r
P
oss
ible
failure
in
1
/0
Ports E2
F3
Po<;si
h
lf':
F
ai
lurf'
in
MRC
or
No
O~ci
l
la
t
or
Signal
54
.
If
the
E
RR
OR
annun
ci
ato
r is
li
t,
verify
the
Er
ror number (
1,
2,
or
3) by repeating
the
power·
up
sel
f
·c
heck, and refer
to
Sect
io
n VIII, T
roubleshooti
n
g.
Power·up self·check
is
initiated
when
the
POWER switch is placed
from
ST8Y to
ON.
3-55. OPERATOR'S MAINTENANCE
3-56. The
only
ma
i
nte
nance the operator sho
uld
no
rm
ally pe
rf
orm
is
replacement
of
the
pri mary p
owe
r fu
se
on
Mo
del
53
158 o
nl
y.
This fu
se
is
locat
ed
within
the
lin
e
Mo
du
le
Assembl
y.
F
or
instru
ctio
ns
on
how
to
change the fuse, refer
to
Sec
tion
It
, l
in
e Voltage
Se
lection.
I CAUTION I
Make sure that o
nly
fuses with
the
required rated t"urrent
and
of
the
slow-blow
type
are used for replat"ement. The use of re-
paired fuses
and
the
short-circuiting of fuse-holders must
be
avoi
ded
.
3·58.
Th
e HP
Mo
del
53
15
A/B
requi
r
es
a
powe
r so
ur
ce
of
1
00,
120, 2
20
, or 240V ac, +5%, - 1
0%,
48
to
66
Hz
s
in
gle
ph
ase.
The selection
of
l
in
e
vo
ltage and in
put
powe
r fu
se
is desc
rib
ed
in
Secti
on
II, paragraph 2-5, Prepa
ra
ti
on
for Use.
3-
59.
The 5
31
5A/
B h
as
a t
wo
-
position
powe
r sw
it
ch
, ST
BY
a
nd
ON. For
531
5A
mo
dels
with
Opt
ion
00
2, it is imp
ort
ant that the
in
s
tru
me
nt rema
in
connected to
th
e
power
source in the ST
BY
mo
de w hen
not
in u
se.
This supp
li
es
p
ower
to
the battery c
ha
rg
in
g ci r
cuit
r
y.
WARNING
POWER
IS
ALWAYS PRESENT AT THE
LINE
SWITCH
AND
TRANSFORMER,
AND
UNREGULATED
DC
IS
PRESENT
WHEN·
EVER
THE
LINE
CORD
IS
ATTACHED. UNPLUGGING THE
POWER
CORD
IS
NECESSARY
TO
REMOVE
ALL
POWER
FROM
THE INSTRUMENT.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5315 A and is the answer not in the manual?

HP 5315 A Specifications

General IconGeneral
BrandHP
Model5315 A
CategoryCash Counter
LanguageEnglish

Related product manuals