Disk drive blanks
The server blade has two disk drive bays. If you only purchased one hard disk, then your server
blade has a hard drive blank installed. Hard drive blanks maintain proper airflow throughout the
server blade.
CAUTION: Populate hard drive bays with a disk drive or a disk drive blank. Operating the server
blade without a disk drive or disk drive blank causes improper airflow and cooling, which can
lead to thermal damage.
Removing a disk drive blank
Remove the component as indicated:
To replace the hard drive blank, slide the blank into the bay until it locks into place. The hard drive
blank is keyed to fit only one way.
Disk drives
The BL860c i2 Server Blade has SAS disk drive slots on the BL860c i2 server blade. The SAS disk
drives have identical LEDs that display the drive status.
114 Removing and replacing components