Place the removed memory module, CF card, or interface module on an antistatic workbench, with
the face upward, or put it into an antistatic bag.
Touch only the edges, instead of electronic components when you observe or move a removed
memory module, CF card, or interface module.
To attach an ESD-preventive wrist strap:
1. Wear the wrist strap on your wrist.
2. Lock the wrist strap tight around your wrist to keep good contact with the skin.
3. Insert the ESD-preventive plug into the ESD-preventive socket.
4. Make sure the rack is well grounded.
CAUTION:
Check the resistance of the ESD-preventive wrist strap for safety. The resistance readin
g
should be in the
range of 1 to 10 megohm (Mohm) between human body and the ground.
EMI
All electromagnetic interference (EMI) sources, from outside or inside of the router and application system,
adversely affect the router in a conduction pattern of capacitance coupling, inductance coupling,
electromagnetic wave radiation, or common impedance (including grounding system) coupling. To
prevent EMI, follow these guidelines:
Take measures against interference from the power grid.
Do not use the router together with the grounding equipment or lightning-prevention equipment of
power equipment, and keep the router far away from them.
Keep the router far away from high-power radio launchers, radars, and equipment with high
frequency or high current.
Use electromagnetic shielding when necessary.
Lightning protection
To better protect the MSR3000 router from lightning, do as follows:
Make sure the grounding cable of the chassis is well grounded.
Make sure the grounding terminal of the AC power receptacle is well grounded.
Install a lightning arrester at the input end of the power supply to enhance the lightning protection
capability of the power supply.
Install a special lightning arrester at the input end of outdoor signal lines (for example, E1/T1 line)
to which interface modules of the router are connected to enhance the lightning protection
capability.
Rack-mounting
Before mounting the router in a standard 19-inch rack, adhere to the following requirements:
The rack is equipped with a good ventilation system.
The rack is sturdy enough to support the router and its accessories.

Table of Contents

Other manuals for HP MSR2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP MSR2000 Series and is the answer not in the manual?

HP MSR2000 Series Specifications

General IconGeneral
BrandHP
ModelMSR2000 Series
CategoryNetwork Router
LanguageEnglish

Related product manuals