26
TROUBLESHOOTING GUIDE
Problem Causes Solutions
Display shows a station is running but
the
and icons are flashing
The sensor is interrupting irrigation,
however the station has been
programmed to override the sensor
Check the sensor override status (see page 23)
Automatic irrigation does not start at
the start time and controller is not in the
System Off mode
•AM/PMoftimeofdaynotsetcorrectly
•AM/PMofstarttimenotsetcorrectly
•StartTimeisdisabled(setforOff)
•ControllerisnotreceivingACpower
•CorrectAM/PMoftimeofday
•CorrectAM/PMofstarttime
•SeeSettingProgramStartTimes(seepage18)
•CheckACpowerconnections
The display shows dashes when the dial
is in the Solar Sync Settings position
•TheSolarSyncsensorisnot
connected to the controller
•TheSolarSyncsensorwiresmayhave
a break in them or a bad connection
Connect the Solar Sync to the “SEN” positions on the
wiring terminal. The display will then show the Region
and Water Adjustment setting.
Run times for a particular station are
too short/too long when using a Solar
Sync sensor
Program Run Time too long/short Solar Sync provides a global seasonal adjustment to the
controller. If a particular station has run times too long
or too short, make the appropriate adjustment to the
program in the controller. Make sure to change seasonal
adjust back to 100% before making changes to program
run times. Do this by turning the dial to the Seasonal
Adjust position and increasing/decreasing the value
to 100%.
Seasonal Adjust seems low •Regiontoohigh
•WaterAdjustmenttoolow
•LocationofSensordoesnotallowfor
full sun
Increase the value on the Water Adjustment scale
(the default setting is 5). If you max out on the Water
Adjustment scale at 10 and still require more seasonal
adjustment, move down one Region (from 4 to 3, for
example) and start at Water Adjustment setting 5. Solar
Sync will immediately update the Seasonal Adjust on the
controller. If it is still too high, repeat the adjustment until
the desired seasonal adjust is showing on the controller.