Specifications
6
138 810770 Operator Manual Echion
Specifications
Echion 15
Dimensions and weights
The shipping weight is for the pump, the pallet, and the packaging. Exact weights are measured at
shipment. Operating weight is for an unpackaged pump with hydraulic fluid.
Electrical
Water
Length 135 cm (53 in.) Shipping weight 850 kg (1,850 lb)
Width 109 cm (43 in.) Operating weight 775 kg (1,700 lb)
Height 101 cm (40 in.)
11.2 kW, 15hp 50 Hz 60 Hz
Voltage 400 V 208 V to 230 V 460 V
Full-load current 23 A 45 A to 41 A 21 A
Primary circuit breaker rating 30 A 60 A 30 A
Minimum Maximum
Cutting water in
Flow 3.8 L/minute (1.0 gallon/minute)
Pressure 2.8 bar (280 kPa / 40 psi) 7.6 bar (760 kPa / 110 psi)
Cutting water out
Flow 1.1 L/minute (0.3 gallon/minute)
Pressure 345 bar (34,500 kPa / 5,000 psi) 4,140 bar (414,000 kPa / 60,000 psi)
Cut-pressure
factory setpoint
4,140 bar (414,000 kPa / 60,000 psi)
Pierce-pressure
factory setpoint
1,380 bar (138,000 kPa / 20,000 psi)
Cooling in and Cooling out
Flow 11.4 L/minute (3 gallons/minute)
Pressure 2.8 bar (280 kPa / 40 psi) 7.6 bar (760 kPa / 110 psi)