Preventive maintenance
60 810770 Operator Manual Echion
Preventive maintenance schedule
These maintenance intervals are recommended guidelines. Find the procedures on the page
numbers listed in the Hours columns.
Interval
Daily
500
1,000
1,500
3,000
6,000
12,000
Before starting the pump
Clean and inspect the pump.
page
39
Check the hydraulic fluid.
page
41
After starting the pump
Examine the pump for leaks or damage.
page
44
Check the hydraulic fluid level.
page
45
Check the hydraulic filter gauge.
page
45
Check the low-pressure water pressure gauges.
page
46
Make sure that the emergency stop operates correctly.
page
46
Intensifier
Repair the high-pressure cylinders, the check valves,
and the low-pressure poppets.
page
66
Replace the high-pressure seal cartridges.
page
69
Intensifier
Replace the high-pressure poppet assemblies.
page
69
Replace the low-pressure poppets and seats.
page
74
Low-pressure water system
Clean the air cooler.
page
78
Bleed-down valve
Repair the bleed-down valve.
page
75
Low-pressure water system
Replace the water filter.
page
80
Test the low-pressure water TDS level.
page
81