Installation
156 810770 Operator Manual Echion
Connect the utilities to the pump
The utility connections are identified with hang tags. The tags have symbols on them that
correspond with the table on page 157.
1. Remove the top cover and the front panel. Refer to Inspect the pump on page 41 for
instructions.
2. Remove the caps from the fittings and the plugs from the utility connections.
CAUTION
Compressed air is an energy source that can eject with force.
Be careful when connecting to and disconnecting from this energy source.
CAUTION
WATER-COOLED SYSTEM
Do not connect the Waste water out hose and the Cooling out line together.
Connecting these hoses can cause cooling water to back up into the system, which can cause
damage to the bleed-down valve and intensifier parts.
CAUTION
To prevent dirty water from entering the bleed-down valve, install the Waste water out hose so
that it is below the bleed-down valve.
Refer to Fittings on page 144 for torque values and information about how to correctly install
high-pressure water fittings.
Parts, tools, and materials
9/16-inch open-ended wrench 1/8-inch NPT male fitting
13/16-inch open-ended wrench 3/8-inch high-pressure male fitting
1-1/16-inch open-ended wrench Two 1/2-inch NPT male fittings
Torque wrench
High-pressure antiseize lubricant such as Blue Goop or PURE Goop
Water-cooled system
1-inch open-ended wrench Two 1/2-inch NPT male fittings
1-3/16-inch open-ended wrench
Keep the caps and the plugs to use if the pump is stored or shipped.