Operation
2
50 810770 Operator Manual Echion
Operation
Stop the pump
Stop the pump remotely
Refer to the OEM’s instructions for turning the pump off.
Stop the pump locally
Use this procedure during normal operation.
On the operator interface, touch the symbol.
The pump, the primary motor, and the intensifier turn off.
The bleed-down valve opens to release high-pressure water from the system.
The supply-water valve closes to stop low-pressure water from entering the system.
No output water pressure shows.
The control circuit stays on.
You can stop the pump from the operator interface while using remote controls. On the
operator interface, touch the symbol to stop the pump.
Refer to Stop the pump on page 50.
Refer to Emergency stop on page 51 for information about the EMERGENCY STOP button.