Installation
Echion Operator Manual 810770 155
4. Use a 13/16-inch open-ended wrench to install the reducing adapter on the short end of
theL-shaped tubing. Use a torque wrench to tighten the fitting to68N∙m(50lbf∙ft).
5. Use a 5/8-inch open-ended wrench to install your 1/4-inch high-pressure tubing from the
cutting head into the top of the reducing adapter. Use a torque wrench to tighten the fitting
to34 N∙m (25 lbf∙ft).
6. Use two 7/16-inch open-ended wrenches and hardware from the kit to attach the tubing to the
tubing bracket with the clamps.