Installation
Echion Operator Manual 810770 167
Pressure Adjustments
Remote Configuration
Maximum This is the maximum pressure that the system can be adjusted to.
The default is4,140bar(60,000psi).
Increments
Increase This is how much the target water pressure increases each time you touch the
symbol on the primary operation screen.
The default is34bar(500psi). The smallest increment is10bar(100psi).
Decrease This is how much that the target water pressure decreases each time you touch
the symbol on the primary operation screen.
The default is34bar(500psi).
Analog Pressure This turns the remote analog pressure input on or off.
Modbus Mode This turns Modbus mode on or off.
When this mode is on, the pump is controlled by Modbus TCP over Ethernet.
Modbus Pressure This turns Modbus control of the pump pressure on or off.
IP Address Enter a static IP address.
Netmask Enter the netmask.
Gateway Enter the gateway.