Installation
7
Echion Operator Manual 810770 167
Installation
Pressure Adjustments
Remote Configuration
Maximum This is the maximum pressure that the system can be adjusted to.
The default is4,140bar(60,000psi).
Increments
Increase This is how much the target water pressure increases each time you touch the
symbol on the primary operation screen.
The default is34bar(500psi). The smallest increment is10bar(100psi).
Decrease This is how much that the target water pressure decreases each time you touch
the symbol on the primary operation screen.
The default is34bar(500psi).
Analog Pressure This turns the remote analog pressure input on or off.
Modbus Mode This turns Modbus mode on or off.
When this mode is on, the pump is controlled by Modbus TCP over Ethernet.
Modbus Pressure This turns Modbus control of the pump pressure on or off.
IP Address Enter a static IP address.
Netmask Enter the netmask.
Gateway Enter the gateway.
>
>