Maintenance
HPR130XD Auto Gas 806330 5-13
Error code troubleshooting error codes 030 to 042, 231 to 234
Error code
number
Name Description Corrective action
030
Gas system
error
Auto Gas
Only
A failure has occurred in
the gas system.
1. Verify that cable number 5 (power supply-to-gas console
control cable) is not damaged and is properly connected
to PCB3 and to the rear of the gas console.
2. Verify that cable number 6 (power supply-to-gas console
power cable) is not damaged and is properly connected
inside the power supply and to the rear of the gas
console.
3. Verify that D1 (+5 VDC) and D2 (+3.3 VDC) are
illuminated on PCB2 inside the gas console. These LEDs
indicate power to PCB2.
4. If power is present at PCB2 and PCB3 and both gas
console cables are good, then PCB2 or PCB3 has failed.
Use the CAN tester to verify which board needs to be
replaced.
031
Primary
231
Secondary
Start lost
Start signal was received
and then lost before an arc
was established.
1. If a mechanical relay is being used to provide the HPR
with a start signal, this relay is either bouncing when
activated or the contacts are faulty. Replace the relay.
2. Inspect interface cable for damage; faulty crimps, or poor
electrical connections.
3. If interface cable is good and a relay is not driving the start
input, the CNC is dropping the start signal before a steady
state arc has been established.
032 Hold timeout
Hold signal was active for
longer than 60 seconds.
1. Check the interface cable for damage. The hold wires may
be short-circuiting inside.
2. The CNC is maintaining this input, it could be waiting for
an IHS complete input from another torch.
3. If CNC interface cable is good and it is a 1-torch system,
change PCB3.
033
Precharge
time-out
Auto Gas
Only
Selection console was not
able to charge the lines to
the correct value.
This is a warning for a possible gas restriction in the leads.
Verify that there are no restrictions in the plasma and shield
hoses, or low inlet-gas pressure.
034
Primary
234
Secondary
Lost current
Chopper 4
HPR400XD
Only
Lost the current signal
from Chopper 4 after
transfer.
1. Verify that the consumable parts are in good condition.
2. Verify proper cut-flow gas settings.
3. Verify pierce delay time.
4. Verify arc did not lose contact with plate while cutting
(hole cutting, scrap cutting, etc).
042
Low nitrogen
(N
2
) gas
pressure
Nitrogen gas pressure
under lower limit of:
2.07 bar (30 psi) – cutting
0.34 bar (5 psi) – marking
During N
2
purge, when
changing between a
fuel gas process and an
oxidizer process.
1. Verify that the nitrogen supply is turned on and inspect
gas supply pressure and volume of gas remaining in
supply tanks.
2. Verify that the gas regulator is set to 8.27 bar (120 psi).
See Setting the supply regulators (Installation section).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance HPR130XD and is the answer not in the manual?

Hypertherm HyPerformance HPR130XD Specifications

General IconGeneral
BrandHypertherm
ModelHyPerformance HPR130XD
CategoryWelding System
LanguageEnglish

Related product manuals