InstallatIon
HPR130XD Auto Gas 806330 3-11
Placement of the power supply
A
The power supply can be moved by forklift but the forks must be long enough to extend the entire length of the base.
Take care when lifting so that the underside of the power supply is not damaged. The forks must also be centered front
to back and side to side to prevent tipping while moving. Fork lift speeds should be kept to a minimum, especially when
making a turn or going around a corner.
• Place the power supply in an area that is free of excessive moisture, has proper ventilation and is relatively clean.
Allow 1 m (3 ft) of space on all sides of the power supply for ventilation and service.
• Coolingairisdrawninthroughthefrontpanelandisexhaustedthroughtherearoftheunitbyacooling
fan. Donot place any filter device over the air intake locations, which reduces cooling efficiency and VOIDS
THEWARRANTY.
• Donotplacethepowersupplyonaninclinegreaterthan10°topreventitfromtoppling.
DANGER
ELECTRIC SHOCK CAN KILL
Remove all electrical connections to the power supply before moving or positioning. Transporting the
unit can cause personal injury and equipment damage.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance HPR130XD and is the answer not in the manual?

Hypertherm HyPerformance HPR130XD Specifications

General IconGeneral
BrandHypertherm
ModelHyPerformance HPR130XD
CategoryWelding System
LanguageEnglish

Related product manuals