SPECIFICATIONS
1-4 powermax
45
Operator Manual
Power supply ratings
Rated open-circuit voltage (U
0
)
CSA/CE, single-phase
CE, 3-phase
275 VDC
Rated output current (I
2
) 20 A to 45 A
Rated output voltage (U
2
) 132 VDC
Duty cycle at 40° C
(See data plate on power supply for
more information on duty cycle.)
50 % (I
2
=45 A, U
2
=132 V)
60 % (I
2
=41 A, U
2
=132 V)
100 % (I
2
=32 A, U
2
=132 V)
Operating temperature 14° to 104° F (-10° to 40° C)
Storage temperature -13° to 131° F (-25° to 55° C)
Power factor
200–240 V CSA, 230 V CE, 1-phase
400 V, 3-phase CE
0.99
0.94
Input voltage (U
1
)/ Input current (I
1
) at
rated output (U
2 MAX
, I
2 MAX
)
(See Voltage configurations in Section 3 for
more information.)
200–240 VAC / 34–28 A (CSA)
230 VAC / 30 A (230 V CE)*
400 VAC 10 A (400 V CE)**
Gas type Air Nitrogen
Gas quality
Clean, dry, oil-free per
ISO 8573-1 Class 1.2.2
99.995 % pure
Recommended gas inlet flow
and pressure
360 scfh @ 90 psi (170 l/min @ 6.2 bar)
* Equipment complies with IEC 61000-3-12.
** Equipment complies with IEC 61000-3-12 provided that the short-circuit power S
sc
is greater
than or equal to 692 KVA at the interface point between the user’s supply and the public
system. It is the responsibility of the installer or user of the equipment to ensure, by consultation
with the distribution network operator if necessary, that the equipment is connected only to a
supply with a short-circuit power S
sc
greater than or equal to 692 KVA.